Using TEMS Investigation Log files with TCPU 6.0
To load TEMS Investigation Log files into TCPU, on the menu bar, go to Utilities->Model Tuning.
When the Model tuning dialog box appears select “Add from file…” and select your TEMS Investigation Log file. Press Open.
• If your log file contains cell information about cells which can be found in the current TCPU project, select “By choosing TCPU cells”.
• If you already know an existing cell and frequency in the log file you can, to spare time, manually enter the cell information using “By specifying air interface parameters”.
• The third alternative is to select your cell from a list of all cells in the log file. Select “By choosing from available air interface parameters”. If the log file is large, this will take some time to update.